Wednesday, 28 May 2014

It's been quite a ride

Well, it really has been quite the ride during the last two years while working full time and completing my Bachelor of Engineering. When you sit down in front of a desk all day at work and then sit in front of a desk at home some more while you do your assignments and write your thesis, you really have to learn to accept that you will not always be able to accomplish everything exceptionally well. You have to learn to prioritise and learn that it sometimes is more important to get a job done and make peace with your decisions when you had to compromise.

But here I am finally, everything done and graded and looking forward to dust off some of the projects which patiently have been staring at me from their shelf.

I never would have thought that I would be able to benefit from having used older GPIB with my home lab equipment for a project at work. I thought that nowadays everything is done with more modern test racks with PXI or similar but it seems that I was mistaken. When projects have a tight budget and the majority of the instruments at your disposal have the legacy GPIB port...it seems foolish not to use that old National Instruments USB-to-GPIB controller from the dumpster and your commercial license of LabVIEW 8.6 to develop and assemble an ATE rack and use it for your production testing. I guess it's a little like those 8-bit micro controllers that certain people claim should be dead and superseded. They're just too good at what they do, they get the job done, they are cheap and they are available. They are not dead just yet.

Monday, 11 June 2012

2G Band pass

This filter was a real pain to get hold of. Since the 2G path is only single-conversion for now (I'm actually working on a front-end improvement with a 2 GHz...10 GHz YIG oscillator), the requirements were pretty demanding. The 1G path actually tunes up to 1200 MHz, so that I was looking for a band pass filter with a pass band in the region from 1.2 GHz to a little over 2 GHz.

I still need to take a picture of the amplitude response but the pass band is from 1200 MHz to just above 2000 MHz with pretty steep skirts. It apparently originates from an old Hewlett Packard spectrum analyser and I got it reasonably cheap off an US-based surplus seller.


Band pass filter for the 2G path.

Update, got screen shots of  the filter response and return loss (looks like I forgot to calibrate, ah well...):

The 3db-bandwidth is about 980 MHz from 1074...2053 MHz.
Not sure if this measurement is meaningful, I forgot to calibrate when I changed the frequency span.  The return loss is about 15 dB or better over the pass band.


Front panel connectors and cable

Inside view of the front panel. I would love to use 0.141" hard line coax to connect the front panel connectors to the slim modules but I'm breaking my fingers trying to bend the coax. I wonder if I could use the semi-rigid 0.141" coax instead, I think to remember that Sam recommended using the hard line coax for high power connections (which the input connectors kind of are). Alternatively, I also have 0.086" aluminium hard line coax.

Wednesday, 6 June 2012

Sunday, 5 February 2012

Rearranging the Enclosure











I only have two of these connectors so I will have to order at least another six.







Tektronix Oscilloscope

I finally found a 1 GHz analog Tektronix 7104. The technology, especially the microchannel CRT, is truly mesmerising for the age it was developed in.

It's in fantastic shape, considering its age. Current plugins are a 7A22 Differential amplifier, 7A29 1 GHz amplifier, 7B10 and 7B15 delayed time base.

Two active 900 MHz FET probes TEK 6201


Quite a few extra plugins. Mainly 7A24 and 7A26 amplifiers as well as some additional time bases.


It replaced my old 20 MHz analog scope from LG. It's still working just fine after 15 years.



DUT Forward / Reverse Switch